Drawing is the language of technology.

The drawing is the law for the manufacturer, hence the Severity to the drawing.

All things, structures that surround us, new and old, once began from a point, from a pencil point. It started with a dot - it sounds a little strange. But imagine, the pencil touched the sheet. Dot. Line. Axial lines, center lines, lines of the inner and outer contours. Lines ... The rulers of the drawing device at the designer's hand moved, and now the main view of the future product began to appear. Then, other projections - top view, side view. It turns out that this is what it is - a detail conceived by us.


For everything that is created by human hands, there is or can be made a drawing.

It is impossible to solve any problems of building a drawing and reading it without the ability to find projections of points.


The front view is the initial view in the drawing, sometimes called the main view.

I get a left view when looking at an object on the left, at a right angle.


Top view is when an object is viewed from above perpendicular to the horizontal plane.


In addition to the front, left, top views, there are right, bottom, and back views.


All these types are basic.


To recognize the size of an object and shape, the required number of species must be present, but no more.


Contactors and starters type PM12-010

1 Purpose of the product


1.1 Contactors and electromagnetic starters of the PM12-010 type are intended for use as components in electric drive control circuits, mainly for use in stationary installations for remote starting by direct connection to the network, stopping and reversing three-phase asynchronous electric motors with a squirrel-cage rotor at voltages up to 660 V alternating current with a frequency of 50 and 60 Hz with a maximum power of up to 2.2 kW at a voltage of 220 V; 4.0 kW at a voltage of 380 V; 5.5 kW at 660 V.


1.2 Starters protect controlled electric motors from overloads of unacceptable duration and from currents arising from the breakage of one of the phases.


2 Product structure


2.1 The starter consists of a housing to which a block of additional contacts can be connected. The configuration of contacts ("open" and "closed") on the additional block, depending on the version, may be different.


2.2 The housing can be disassembled without any additional tools, for example, to replace the coil, or to clean the contacts.


3 Basic technical data


3.1 Rated current of the contacts of the main circuit, A ——— 10


3.2 Rated current of auxiliary circuit contacts, A ——— 10


3.3 Rated voltage of the closing coils:


- 24, 36, 40, 48, 110, 127, 220, 230, 240, 380, 400, 415, 440, 500, 660 V AC with a frequency of 50 Hz;


- 24, 36, 48, 110,115, 220, 230, 380, 415, 440 V 60 Hz.


3.4 Mechanical, switching endurance and permissible switching frequency per hour must correspond to table 1.


Table 1


3.5 The rated currents and rated operating currents of the contacts of the main circuit of non-reversing contactors and starters, and their switching durability in the AC-4 application category must correspond to the data in Table 2.


table 2


4 Service life of contactors and starters before decommissioning is 16 years.